Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 52
Filtrar
1.
PLoS One ; 19(2): e0286672, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38408064

RESUMO

This ex vivo study aimed to investigate surface roughness and substance loss after treatment with different professional cleaning methods and to determine whether subsequent polishing with a rubber cup and polishing paste is necessary. Samples (flat and natural surfaces) of human enamel and dentin were prepared (baseline) and treated with either a curette, air-polishing with erythritol, a rubber cup and polishing paste, or a combination thereof (treatment). Subsequently, all samples were immersed in an ultrasonic bath (ultrasonic) to remove residues from the treatment procedures. The surface roughness values sRa and sRz as well as tissue loss were measured profilometrically. Linear regression models were used to compare group differences (roughness and loss) considering the corresponding baseline value. The significance level was set at p<0.05. sRa increased significantly after treatment with curettes or air-polishing with erythritol in both enamel (p<0.001) and dentin (p<0.001) of flat samples. The same effect was observed for sRz in dentin (p<0.001) but not for enamel compared to negative control. Polishing with a rubber cup and paste alone had no significant effect on roughness values. When combined with other treatments, the effect of curette or air-polishing with erythritol dominated the effect. In enamel, none of the tested methods led to measurable tissue loss. In dentin, air-polishing with erythritol caused ≤50% tissue loss compared to the curette. Conclusively, for enamel, treatment effects on roughness were measurable but of limited clinical relevance. For dentin, air-polishing resulted in a smaller but insignificant roughness increase and less tissue loss compared to the curette. Polishing with a rubber cup and paste did not affect surface roughness. Regarding the clinical application, the use of air-polishing seems to be a less invasive procedure than using a curette; polishing with rubber cup and paste offers no advantage in terms of reducing roughness as a final procedure.


Assuntos
Eritritol , Borracha , Humanos , Propriedades de Superfície , Polimento Dentário
2.
J Adhes Dent ; 26(1): 1-10, 2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-38224111

RESUMO

PURPOSE: To investigate the microtensile bond strength (µTBS) to dentin in class-I cavities using different layering techniques, adhesive application modes, and aging. MATERIALS AND METHODS: 150 caries-free human molars were randomly assigned to 8 experimental and 2 control groups (n=15 teeth/ group). For each tooth, a standardized class-I cavity was prepared (4x4x4 mm) and pretreated with a universal adhesive (self-etch or etch-and-rinse mode). Incrementally layered restorations served as the control. In the experimental groups, either lining with bulk-fill flowable composite and a layering technique, bulk filling, or the snowplow technique with one or two layers of viscous composite were applied. Four microsticks were obtained from each cavity. Half were tested initially and the other half after aging (thermocycling, 15,000 cycles, 5-55°C, n=30 sticks/group). Tobit regression was used for analyzing group differences, including analysis of interactions, Pearson's chi-squared test or Fishers's exact test for fracture analyses (significance level 0.05). RESULTS: Regression analysis showed significant differences in µTBS between groups initially and after aging. In both etching modes, lining with a bulk-fill flowable composite and layering technique achieved the highest µTBS both initially and after aging. In contrast to the etching mode (self-etch < etch-and-rinse), aging did not influence µTBS significantly. The predominant failure types were adhesive and mixed, with a significantly lower number of pre-test failures in the etch-and-rinse groups. CONCLUSION: The etch-and-rinse mode achieves higher µTBS in class-I cavities compared to the self-etch mode. The lining technique with bulk-fill flowable composite as well as the snowplow technique yielded the highest µTBS after aging, whereas bulk filling and its combination with the snowplow technique resulted in lower µTBS.


Assuntos
Colagem Dentária , Cimentos Dentários , Humanos , Adesivos Dentinários , Dentina , Resistência à Tração , Teste de Materiais , Resinas Compostas/química , Cimentos de Resina/química
3.
J Dent ; 142: 104852, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38244909

RESUMO

OBJECTIVES: The aim of this study was to compare the dentin adhesion of bulk-fill composites in high C-factor class I-cavities before and after thermocycling to a control group using incremental layering technique. METHODS: A standardized class I-cavity was prepared into 195 human molars, then different universal adhesives were applied either in self-etch or etch & rinse mode, and the cavity was filled according to each materials application protocol. The material combinations used were a conventional layered composite as control, the respective bulk-fill product, two other bulk-fill composites made by different manufacturers, with one of them being tested using two different polymerization times. Furthermore, one thermoviscous bulk-fill composite and one self-adhesive restorative were examined of which the latter can only be applied in self-etch mode. In each group the dentin adhesion to the cavity bottom was measured using microtensile bond strength test initially (24 h water storage) and after thermocycling. All results were statistically analyzed using STATA 17.0. RESULTS: The statistical analysis showed significant differences between the control and the experimental groups (p < 0.001). The highest mean bond strength before (14.8 ± 10.7 MPa) and after aging (14.2 ± 11.5 MPa) was measured for the etch & rinse-control group. Among the bulk-fill groups, the etch & rinse technique consistently showed higher bond strengths. Bond strength of groups with shortened polymerization did not exceed 2.1 MPa. The bond strength of the self-adhesive restoration material was low before and after thermocycling (2.7 MPa/ 0.0 MPa). Groups with low bond strength values showed a high number of pre-testing-failures. CONCLUSIONS: Bulk-fill materials used in high C-factor class I-cavities showed lower bond strength during self-etch application. The same applies for a shortened polymerization regime, which cannot be recommended for high C-factor cavities. CLINICAL SIGNIFICANCE: Today, a large variety of materials and application techniques can be used when placing an adhesive restoration. Whether new instead of established procedures should be applied in high C-factor cavities has to be critically assessed, as they are a demanding scenario for adhesive restorations.


Assuntos
Colagem Dentária , Cárie Dentária , Humanos , Adesivos Dentinários/química , Resinas Compostas/química , Cimentos Dentários , Colagem Dentária/métodos , Cimentos de Resina , Dentina , Teste de Materiais , Resistência à Tração , Adesivos
4.
Caries Res ; 57(3): 265-275, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37725923

RESUMO

Sodium hexametaphosphate (HMP) as toothpaste additive is claimed to reduce erosive tooth wear and to stabilize stannous ions. However, little is known about the impact of concentration and its interactions with fluoride (F) or stannous+fluoride ions (F/Sn) on enamel erosion and erosion-abrasion. In a 10 day cyclic in vitro erosion-abrasion model, 320 flat human enamel specimens were divided into ten groups (n = 32 each) and daily subjected to six erosive challenges (0.5% citric acid, 2 min) and two toothpaste suspension applications (2 min, 1:3 F-free toothpaste:mineral-salt solution, 0.23% sodium gluconate). Half of specimens per group were additionally brushed twice/day (200 g, 15 s) during suspension immersion. Nine suspensions contained HMP (0.25%, 1.75%, 3.25%), either on its own or combined with F (373 ppm F-) or F/Sn (800 ppm Sn2+, 373 ppm F-). One suspension contained sodium gluconate only (NegContr). After 10 days, specimens' surfaces were analysed with profilometry, energy dispersive X-ray spectroscopy, and scanning electron microscopy. Tissue loss (µm, mean ± standard deviation) in NegContr was 10.9 ± 2.0 (erosion), 22.2 ± 1.6 (erosion-abrasion). Under erosive conditions, only 0.25% HMP in any combination and 1.75% HMP with F/Sn reduced loss significantly (-28% to -54%); 3.25% HMP without F and F/Sn increased loss significantly (+35%). With additional abrasion, no suspension reduced loss significantly compared to NegContr, instead, in groups without F and F/Sn or with 3.25% HMP loss was increased (+15% to +30%). Conclusively, at higher concentrations, HMP increased erosive tooth wear and seemed to reduce anti-erosive effects of fluoride and stannous ions.


Assuntos
Abrasão Dentária , Erosão Dentária , Desgaste dos Dentes , Humanos , Cremes Dentais/farmacologia , Cremes Dentais/química , Fluoretos/farmacologia , Erosão Dentária/prevenção & controle , Abrasão Dentária/etiologia , Abrasão Dentária/prevenção & controle , Fluoreto de Sódio/farmacologia , Esmalte Dentário
5.
Nutrients ; 15(15)2023 Jul 27.
Artigo em Inglês | MEDLINE | ID: mdl-37571281

RESUMO

Although numerous studies have been published investigating the relationship between various dietary components and inflammatory periodontal disease, it has not yet been possible to clearly distinguish between periodontally healthy and unhealthy diets. This clinical study aimed to assess the association of specific food ingredients and physical activity on local and systemic inflammatory signs in experimentally induced gingivitis. Thirty-nine non-smoking periodontally healthy volunteers (mean age 23.2 ± 3.8 years) refrained from oral hygiene in the right maxilla for 21 days to induce an experimental gingivitis. Clinical examination (baseline and day 21) included plaque index, bleeding on probing (BOP), gingival crevicular fluid volume and high sensitive C-reactive protein levels (blood sample). Accompanying the intervention, volunteers documented with validated questionnaires their physical activity converted into metabolic equivalent (MET) and their nutrition converted into the dietary inflammatory index (DII). Significantly lower BOP (p = 0.039) was found for subjects with a more anti-inflammatory DII than for those with a more pro-inflammatory DII; higher MET values were correlated with lower BOP at day 21 (correlation coefficient -0.36). The results show an influence of nutrition and physical activity on periodontal inflammation signs. The DII may be a suitable parameter to verify the relationship between nutrition and inflammatory periodontal diseases.


Assuntos
Gengivite , Doenças Periodontais , Humanos , Adulto Jovem , Adulto , Doenças Periodontais/metabolismo , Inflamação/metabolismo , Líquido do Sulco Gengival/metabolismo , Exercício Físico
6.
Jpn Dent Sci Rev ; 59: 114-128, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36950225

RESUMO

Acute dental pain is a common issue leading to dental consultation. Besides causal therapy, patients are treated with acupuncture, but efficacy in acute dental pain is still not clarified. We aimed to evaluate results of recent research to estimate the efficacy of acupuncture compared to pain-relieving approaches in treatment of acute dental pain. A systematic review of controlled trials being published between database inception and 2020 were conducted to evaluate the efficacy of acupuncture (alone or as complementary therapy) compared to local anesthesia or conventional analgesic medications in acute dental pain (intraoperatively and postoperatively) and to clarify whether acupuncture reduces the use of postoperative analgesic medications. Of 1672 publications, 23 publications met the inclusion criteria. From these, 11 randomized controlled trials (n = 668) reported on the efficacy of acupuncture on postoperative acute dental pain. Patients, who received acupuncture, showed lower pain scores postoperatively compared to sham acupuncture (Relative Risk -0.77, 95% Confidence interval -1.52 to -0.03). Overall, the results suggest a potential role of acupuncture in improving acute dental pain intraoperatively and postoperatively as well as improving the efficacy of local anesthesia, but the results are limited due to methodological shortcomings emphasizing the necessity for future high-quality research.

7.
Artigo em Inglês | MEDLINE | ID: mdl-36767148

RESUMO

In diagnostic accuracy studies, the test of interest is typically applied only once in each patient. This paper illustrates some possibilities that arise when diagnoses are carried out by a sufficiently large number of multiple raters. In a dental study, sixty-one examiners were asked to diagnose 49 tooth areas with different grades of tissue loss (minor, moderate, and advanced) to decide whether dentine was exposed (positive status) or not (negative status). The true status was determined by histology (reference). For each tooth, the rate of correct decisions reflecting the difficulty to diagnose this tooth and the positive rate reflecting the perception of the tooth by the raters was computed. Meta-analytical techniques were used to assess the inter-tooth variation and the influence of tooth-specific factors on difficulty or perception, respectively. A huge variation in diagnostic difficulty and perception could be observed. Advanced tissue loss made diagnoses more difficult. The background colour and tissue loss were associated with perception and may hint to cues used by the raters. The use of multiple raters in a diagnostic accuracy study allows detailed investigations which make it possible to obtain further insights into the decision-making process of the raters.


Assuntos
Dente , Humanos , Odontologia
8.
Biopsychosoc Med ; 16(1): 25, 2022 Dec 09.
Artigo em Inglês | MEDLINE | ID: mdl-36494736

RESUMO

OBJECTIVE: Persistent Idiopathic Facial Pain (PIFP) is a pain syndrome with missing evidence-based therapy recommendations. According to the biopsychosocial pain model, multidisciplinary pain treatment (MPT) offers a promising therapeutic option for chronic pain syndromes. MPT is an interprofessional treatment procedure, consisting of medical, physiotherapeutic and psychotherapeutic treatment units, which has not yet been studied in PIFP. METHODS: This retrospective study included 25 patients with PIFP, who had been treated with MPT. Pain intensity on the numerical rating scale (NRS), perceived disability, habitual well-being, as well as anxiety/depression and stress scales were recorded. Moreover, the patients evaluated the efficacy of each type of the single therapeutic interventions. RESULTS: There was a highly significant decrease in the characteristic pain intensity. Also habitual well-being improved significantly, as did anxiety and depression. The perceived disability and stress also improved, but without statistical significance. Physiotherapy was rated as the most effective therapeutic unit. Among the medical measures, consultations took first place (40% of the participants). Nearly three-fourths of the patients (72%) would recommend MPT. CONCLUSION: The present study shows beneficial outcomes in patients with PIFP following MPT. Patients evaluate physiotherapeutic treatment as particularly efficacious. Therefore, MPT can be considered as a therapeutic option in patients with PIFP.

9.
Polymers (Basel) ; 14(19)2022 Oct 09.
Artigo em Inglês | MEDLINE | ID: mdl-36236172

RESUMO

Different agents have been proposed to prevent the progression of acid induced dental substance losses, which are called erosive tooth wear (ETW), such as fluorides, calcium, and phosphate-based products; however, there is a need for a further increase in efficacy. Recently, the ability of polymers to interact with the tooth surface, forming acid resistant films, has come into the focus of research; nevertheless, there is still the need for a better understanding of their mode of action. Thus, this article provides an overview of the chemical structure of polymers, their mode of action, as well as the effect of their incorporation into oral care products, acid beverages, and antacid formulations, targeting the prevention of ETW. Recent evidence indicates that this may be a promising approach, however, additional studies are needed to confirm their efficacy under more relevant clinical conditions that consider salivary parameters such as flow rate, composition, and clearance. The standardization of methodological procedures such as acid challenge, treatment duration, and combination with fluorides is necessary to allow further comparisons between studies. In conclusion, film-forming polymers may be a promising cost-effective approach to prevent and control erosive demineralization of the dental hard tissue.

10.
PLoS One ; 17(10): e0276686, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36288348

RESUMO

Planimetry is a reliable method for detecting and monitoring plaque. Until now, this method has mainly been applied to conventional-camera images, which is difficult and time-consuming in relation to the entire dentition. Today, 3D-intraoral-scans are well suited for imaging the entire dentition and are therefore an efficient and feasible alternative. 3D-intraoral-scans have already proven successful for the quantification of plaque based on a plaque index. Therefore, aim of this study was to investigate whether images from 3D-intraoral-scans are also suitable for valid planimetric plaque measurements and monitoring; intraoral-camera images served as a reference. Twenty subjects (27.5±1.2 years) were included. Plaque was disclosed at three different time points: habitual plaque (T1), after 72 h without oral hygiene (T2) and after subsequent tooth brushing (T3) and quantified using 3D-intraoral-scans and intraoral-camera images (intraoral-camera CS 1500, intraoral-scanner CS 3600; Carestream Dental, Germany). The percentage of the plaque-covered surface of the total surface area (P%) was determined with a software specially programmed for this purpose using images from 3D-intraoral-scans of the oral and vestibular surfaces of the Ramfjord teeth (16, 21, 24, 36, 41, and 44); the intraoral-camera images of the vestibular surfaces of 16 and 36 served as reference. P% from images of the 3D-intraoral-scan and the intraoral-camera revealed a very good correlation (r = 0.876; p ≤ 0.001); the Bland-Altmann analysis showed a good agreement with no proportional and a very minor systematic bias with slightly higher values from images of the 3D-intraoral-scan. Further, P% measurements of the images of the 3D-intraoral-scan were able to detect changes in plaque levels, showing a 47% (p ≤ 0.001) increase in P% from T1 to T2 and a 43% (p ≤ 0.001) decrease after toothbrushing (T3). Planimetry using images of the 3D-intraoral-scan seems to be a suitable tool for whole mouth planimetry to record and monitor dental plaque.


Assuntos
Placa Dentária , Dente , Humanos , Placa Dentária/diagnóstico por imagem , Dente/diagnóstico por imagem , Dentição , Escovação Dentária , Software , Imageamento Tridimensional/métodos
11.
Sci Rep ; 12(1): 9627, 2022 06 10.
Artigo em Inglês | MEDLINE | ID: mdl-35688889

RESUMO

The effects of the particle fraction in toothpastes in the context of erosion and erosive tooth wear has not been fully elucidated. Thus, aim of this study was to investigate experimental toothpastes, each with one specific particle type. Toothpastes with seven different types of silica or alumina were prepared as slurry either with or without active ingredients (NaF or F/Sn). Human enamel samples were exposed to a cyclic erosion/abrasion model, and were either treated with the respective slurries only or additionally brushed in a brushing machine. Tissue loss was profilometrically monitored. After treatment with slurries without active ingredients or with NaF, tissue loss increased significantly within groups over time (p < 0.001 each). At the end of the trial, there were minor differences between groups (not exceeding 10-20%; p > 0.05 for most comparisons). After treatment with the F/Sn slurries, tissue loss stagnated completely over time, with the exception of one silica type and alumina, but both still reduced tissue loss by 40-50% (compared to control p < 0.001 each). Relative to the type of the active ingredient, the particle type seems to be a secondary factor for the efficacy of toothpastes on erosion and erosive tooth wear in enamel.


Assuntos
Quitosana , Abrasão Dentária , Erosão Dentária , Desgaste dos Dentes , Óxido de Alumínio , Quitosana/farmacologia , Esmalte Dentário , Humanos , Dióxido de Silício , Fluoreto de Sódio/farmacologia , Erosão Dentária/prevenção & controle , Escovação Dentária , Cremes Dentais/farmacologia
12.
Sci Rep ; 12(1): 4153, 2022 03 09.
Artigo em Inglês | MEDLINE | ID: mdl-35264778

RESUMO

Controversial results showing that deciduous teeth are more susceptible to erosion than permanent teeth might be related to study designs. We investigated how different conditions (pH: 3.0, 4.0, 5.0; acid agitation: gentle or vigorous; acid exposure times: 1-5 min) affect the susceptibility of both teeth to erosion. Enamel specimens (90 deciduous, 90 permanent) were distributed into groups (n = 15 permanent, n = 15 deciduous) according to acid pH (pH 5, 4 or 3) and agitation (gentle or vigorous) during erosive challenge. Both milder (less incubation time, gentle agitation, and higher pH) and more severe (longer incubation times, vigorous shaking, and lower pH) conditions were used. Demineralization was measured by relative surface microhardness (rSMH) and calcium released to the acid. Demineralization increased gradually for both teeth with increasing incubation time, agitation (gentle or vigorous), and with decreasing acid pH. The differences between deciduous and permanent teeth depended on the protocol design and assessment method. Under milder conditions, demineralization was better detectable with rSMH. Under more severe conditions, differences were more perceptible with calcium analyses. Differences exist in the susceptibility to erosion between deciduous and permanent teeth, but they are only distinguishable when the appropriate assessment method is used for the specific erosive condition.


Assuntos
Erosão Dentária , Ácidos , Cálcio , Dentição Permanente , Dureza , Humanos , Erosão Dentária/diagnóstico , Erosão Dentária/etiologia , Dente Decíduo
13.
PLoS One ; 17(2): e0263722, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35167618

RESUMO

Detecting and monitoring dental plaque is an important issue in research and clinical practice. In this context, new digital imaging methods that permit permanent documentation of the clinical findings could be promising tools. The aim of the study was therefore to investigate whether disclosed plaque can be reliably visualised on 2D and 3D images captured with digital intraoral imaging devices. Clinical examination was the reference method. Twenty subjects (27.5±1.2 years) were included and plaque was measured at three different stages: habitual plaque (T1), after 72 h without oral hygiene (T2) and after a subsequent habitual brushing exercise (T3). At each time point, plaque was disclosed followed by the clinical examination and capturing the 2D and 3D images (intraoral-camera CS 1500 and intraoral-scanner CS 3600; Carestream Dental, Germany). Plaque amounts were recorded on oral and vestibular surfaces of the Ramfjord-teeth (16, 21, 24, 36, 41, 44) using the Rustogi-modified-Navy-Plaque-Index (RMNPI) and expressed as percentage of plaque-containing RMNPI areas of all RMNPI areas. At T1, percentages (mean±SD) obtained from the clinical examination, 2D and 3D images were 62.2±10.6, 65.1±10.0 and 64.4±10.6 resp. increasing to 76.9±8.0, 77.9±8.6 and 77.5±9.4 resp. at T2. After toothbrushing (T3), values decreased to 56.3±11.1, 58.2±12.1 and 61.2±10.8 resp. All methods were able to show statistically significant changes in plaque amounts at the different time points with in part statistically significant but minor differences between them. The Bland-Altmann analysis revealed a good agreement between values from both 2D and 3D images with the clinical examination. The agreement of the scores obtained with the both image-based methods for the single RMNPI areas with the clinical examination was mainly classified as substantial to almost perfect. Amounts of plaque can be reliably detected and monitored on 2D images from an intraoral camera and on 3D images from an intraoral scanner.


Assuntos
Placa Dentária/diagnóstico por imagem , Imageamento Tridimensional/métodos , Adulto , Feminino , Humanos , Masculino , Fotografia Dentária , Estudos Prospectivos
14.
PLoS One ; 17(2): e0264306, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35202439

RESUMO

Many preventive approaches in dentistry aim to improve oral health through behavioural instruction or intervention concerning oral health behaviour. However, it is still unknown which factors have the highest impact on oral health behaviours, such as toothbrushing or regular dental check-ups. Various external and internal individual factors such as education, experience with dentists or influence by parents could be relevant. Therefore, the present observational study investigated the influence of these factors on self-reported oral heath behaviour. One hundred and seventy participants completed standardized questionnaires about dental anxiety (Dental Anxiety Scale (DAS), and dental self-efficacy perceptions (dSEP)). They also answered newly composed questionnaires on oral hygiene behaviours and attitudes, current and childhood dental experiences as well as parental oral hygiene education and care. Four independent factors, namely attitude towards oral hygiene, attitude towards one's teeth, sense of care and self-inspection of one's teeth were extracted from these questionnaires by rotating factor analysis. The results of the questionnaires were correlated by means of linear regressions. Dental anxiety was related to current negative emotions when visiting a dentist and negative dental-related experiences during childhood. High DAS scores, infantile and current negative experiences showed significant negative correlations with the attitude towards oral hygiene and one's teeth. Dental anxiety and current negative dental experiences reduced participants' dental self-efficacy perceptions as well as the self-inspection of one's teeth. While parental care positively influenced the attitude towards one's teeth, dental self-efficacy perceptions significantly correlated with attitude towards oral hygiene, self-inspection of one's teeth and parental care. Dental anxiety, dental experiences, parents' care for their children's oral hygiene and dental self-efficacy perceptions influence the attitude towards oral hygiene and one's own oral cavity as well as the autonomous control of one's own dental health. Therefore, oral hygiene instruction and the development of patient-centred preventive approaches should consider these factors.


Assuntos
Assistência Odontológica/psicologia , Comportamentos Relacionados com a Saúde , Educação em Saúde Bucal , Higiene Bucal/psicologia , Adolescente , Adulto , Atitude Frente a Saúde , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Autorrelato , Escovação Dentária , Adulto Jovem
15.
Clin Oral Investig ; 26(3): 2909-2919, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35018500

RESUMO

OBJECTIVES: To evaluate interdental biofilm reduction and composition after powered toothbrushing with a side-to-side (sonic) toothbrush compared to manual toothbrushing following single brushing exercises in periodontally healthy young adults. MATERIALS AND METHODS: All participants brushed with a side-to-side toothbrush without toothpaste in four different modes: toothbrush (a) inactivated without instruction (OFF-NI), (b) activated without instruction (ON-NI), (c) inactivated with instruction (OFF-I), and (d) activated with instruction (ON-I) at consecutive visits (single brushing exercises). Before and after brushing, the Approximal Plaque Index (API) was assessed at three interdental spaces and plaque samples were taken from two interdental sites. Biofilm reduction and composition were analyzed microbiologically by total bacterial load and 16S rRNA sequencing. RESULTS: Thirty participants (age: 22.9 ± 2.5 years) completed the study. Most participants showed no or incomplete plaque removal assessed by API following single brushing exercises, while the frequency of API reduction was higher after ON-NI compared to OFF-I (p = 0.023). Irrespective of the brushing mode, a significant reduction of total bacterial load was detected with lower bacterial counts after OFF-NI compared to ON-NI (p = 0.008) and ON-I (p = 0.007). Biofilm composition showed slight changes in the relative abundances of bacterial taxa, regardless of the brushing mode. CONCLUSIONS: Manual and powered toothbrushing with a side-to-side toothbrush, with and without instruction, showed incomplete interdental biofilm removal in periodontally healthy young adults following single brushing exercises. CLINICAL RELEVANCE: Data has to be validated in further studies on other groups, however, in periodontally healthy young adults, additional devices seem to be necessary for sufficient interdental cleaning.


Assuntos
Biofilmes , Escovação Dentária , Adulto , Índice de Placa Dentária , Desenho de Equipamento , Humanos , RNA Ribossômico 16S , Adulto Jovem
16.
PLoS One ; 16(12): e0261496, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34937069

RESUMO

Clinical studies on the efficacy of sonic toothbrushes show inconsistent results, most studies have been conducted without sufficient supervision of appropriate toothbrush usage. Aims of the explorative clinical trial were therefore to investigate whether the usage of an activated sonic toothbrush reduces plaque more effectively than an inactivated one used as a manual toothbrush, and to which extent the correct use of such toothbrush plays a role in its efficacy. The clinical trial was designed as a video-controlled interventional study. Thirty participants (mean (±SD) age 22.9 (±2.5) years) were included, areas of interest were the buccal surfaces of the upper premolars and the first molar (partial mouth recording). Toothbrushing was performed without toothpaste in a single brushing exercise under four different conditions: switched off, habitually used as manual toothbrush, no instruction; switched on, habitually used as powered toothbrush, no instruction; switched off, used as manual toothbrush, instruction in the Modified Bass Technique; switched on, used as powered toothbrush, instruction in a specific technique for sonic toothbrushes. Brushing performance was controlled by videotaping, plaque was assessed at baseline (after 4 days without toothbrushing) using the Rustogi modified Navy-Plaque-Index and planimetry. Main study results were that plaque decreased distinctly after habitual brushing regardless of using the sonic brush in ON or OFF mode (p for all comparisons < 0.001). After instruction, participants were able to use the sonic brush in ON mode as intended, with only minor impact on efficacy. Using the toothbrush in OFF mode with the Modified Bass Technique was significantly less effective than all other conditions (p for all comparisons < 0.001). Under the conditions used, the sonic toothbrush was not more effective when switched on than when switched off, and there was no evidence that the correct use of the toothbrush was more effective than the habitual use.


Assuntos
Índice de Placa Dentária , Gengivite , Escovação Dentária/instrumentação , Adulto , Feminino , Gengivite/diagnóstico , Gengivite/prevenção & controle , Humanos , Masculino , Estudos Prospectivos , Som , Escovação Dentária/métodos , Gravação em Vídeo , Adulto Jovem
17.
Antibiotics (Basel) ; 10(5)2021 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-33921981

RESUMO

The aim of this randomized, controlled clinical trial was to isolate and identify viable microorganisms in the saliva of study participants that continuously used a stannous and fluoride ion (F/Sn)-containing toothpaste and mouth rinse over a period of three years in comparison to a control group that used stannous ion free preparations (noF/Sn) over the same time period. Each group (F/Sn and noF/Sn) included 16 participants that used the respective oral hygiene products over a 36-month period. Stimulated saliva samples were collected at baseline (T0) and after 36 months (T1) from all participants for microbiological examination. The microbial composition of the samples was analyzed using culture technique, matrix-assisted laser desorption ionization-time of flight (MALDI-TOF) mass spectrometry, and 16S rDNA Polymerase Chain Reaction (PCR). There were only minor differences between both groups when comparing the absolute values of viable microbiota and bacterial composition. The treatment with F/Sn led to a slight decrease in disease-associated and a slight increase in health-associated bacteria. It was shown that the use of stannous ions had no negative effects on physiological oral microbiota even after prolonged use. In fact, a stabilizing effect of the oral hygiene products containing stannous ions on the health-associated oral microbiota could be expected.

18.
Sci Rep ; 11(1): 5285, 2021 03 05.
Artigo em Inglês | MEDLINE | ID: mdl-33674643

RESUMO

The application of stannous ions in combination with fluoride (F/Sn) is one of the central strategies in reducing erosive tooth wear. F/Sn efficacy can be enhanced by adding chitosan, a positively charged biopolymer. For patients with low saliva flow, this efficacy, however, is not sufficient, making further improvement desirable. This could be achieved by combining chitosan with other molecules like mucin, which together might form multilayers. This in-vitro study aimed to investigate the effect of chitosan, mucin, F/Sn and combinations thereof on enamel erosion and erosion-abrasion. Human enamel samples (n = 448, 28 groups) were cyclically eroded or eroded-abraded (10 days; 6 × 2 min erosion and 2 × 15 s/200 g abrasion per day). Samples were treated 2 × 2 min/day with solutions containing either, chitosan (50 or 500 mPas), porcine gastric mucin, F/Sn or combinations thereof after abrasive challenge. Tissue loss was measured profilometrically, interaction between hard tissue and active agents was assessed with energy dispersive spectroscopy and scanning electron microscopy. Chitosan and F/Sn showed the expected effect in reducing tissue loss under erosive and under erosive-abrasive conditions. Neither mucin alone nor the combinations with mucin showed any additional beneficial effect.


Assuntos
Quitosana/farmacologia , Esmalte Dentário/efeitos dos fármacos , Lubrificantes/farmacologia , Mucinas/farmacologia , Fluoretos de Estanho/farmacologia , Abrasão Dentária/prevenção & controle , Erosão Dentária/prevenção & controle , Esmalte Dentário/diagnóstico por imagem , Humanos , Microscopia Eletrônica de Varredura/métodos , Espectrometria por Raios X/métodos , Abrasão Dentária/diagnóstico por imagem , Erosão Dentária/diagnóstico por imagem , Escovação Dentária , Cremes Dentais/química
19.
Caries Res ; 54(1): 2-6, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31610535

RESUMO

Our understanding of erosive tooth wear and its contributing factors has evolved considerably over the last decades. New terms have been continuously introduced, which frequently describe the same aspects of this condition, whereas other terms are being used inappropriately. This has led to unnecessary confusion and miscommunication between patients, professionals, and researchers. A group of 15 experts, selected by the European Organization for Caries Research (ORCA) and the Cariology Research Group of the International Association for Dental Research (IADR), participated in a 2-day workshop to define the most commonly used terms in erosive tooth wear. A modified Delphi method was utilized to reach consensus. At least 80% agreement was achieved for all terms discussed and their definitions related to clinical conditions and processes, basic concepts, diagnosis, risk, and prevention and management of erosive tooth wear. Use of the terms agreed on will provide a better understanding of erosive tooth wear and intends to enable improved communication on this topic.


Assuntos
Cárie Dentária , Atrito Dentário , Desgaste dos Dentes , Consenso , Cárie Dentária/prevenção & controle , Humanos , Erosão Dentária/prevenção & controle , Desgaste dos Dentes/prevenção & controle
20.
J Dent ; 92: 103247, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31743693

RESUMO

OBJECTIVES: Chitosan (Ch) in F/Sn-toothpastes can increase toothpastes' anti-erosive efficacy. Whether efficacy can be further increased by changing chitosan's viscosity was study aim. METHODS: 192 human enamel specimens were assigned to 2 × 6 groups (n = 16 each): Four F/Sn (500 ppm F-, 800 ppm Sn2+) toothpastes with chitosan (0.5 %, viscosity 50, 500, 1000 or 2000 mPas), negative-control (no F/Sn/chitosan), positive-control (F/Sn, no chitosan). The study was conducted in two experiments (E1/E2). Specimens were cyclically demineralised (10 d, 6 × 2 min/d; 0.5 % citric acid); half of groups (E1) was exposed to toothpaste slurries (2 × 2 min/d), the other half was additionally brushed (2 × 15 s/d, E2). Tissue loss (mean ±â€¯SD, µm) was quantified profilometrically. Element analysis (EDX, wt%) on specimen surfaces and on toothpastes' particulate fraction and SEM analysis of specimen surfaces were performed. RESULTS: Tissue loss in negative-controls (E1/E2) was 4.96 ±â€¯1.55/12.76 ±â€¯2.45. Toothpastes with active agents (AA) reduced tissue loss compared to negative-control (p < 0.0001). E1: All AA caused precipitates, being the thickest after Ch500. Chitosan increased carbon retention, not tin retention. E2: Only Ch1000 increased efficacy (-0.97 ±â€¯4.48) compared to positive-control (2.98 ±â€¯1.32; p = 0.05). EDX showed comparable carbon values in all AA; tin content was higher in Ch1000 (6.5 ±â€¯3.4) compared to other AA (range: 3.8 ±â€¯0.3-4.3 ±â€¯1.3). On abrasives, tin adsorption was decreased by all chitosans. SEM revealed minor structural differences. CONCLUSIONS: Chitosan viscosity has impact on efficacy of F/Sn toothpastes. Under erosive/abrasive conditions Ch1000 showed the best protective effect with higher tin retention on surfaces and lower tin absorption by abrasives. CLINICAL SIGNIFICANCE: The biopolymer chitosan shows protective effect against enamel erosion and erosion/abrasion when used in an F/Sn toothpaste with specific viscosity.


Assuntos
Quitosana , Abrasão Dentária , Erosão Dentária , Esmalte Dentário , Humanos , Fluoreto de Sódio , Fluoretos de Estanho , Escovação Dentária , Cremes Dentais , Viscosidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...